The
Contactor is an electrically controlled switch which is used for
converting/switching the electrical power circuit. The power
consumption of the contactor is comparatively less than an electrical
switch as it is directly controlled by a circuit. It has 24-volt coil
electromagnet controlling 230-volt motor switch.
The
power circuit switches are also used for the Power Contactors. When a
realy functions as the switch, it provides electrical power through
the contactors. Contactors have multiple functions, contactors are
normally open the current and sometimes when the current load shuts
off, then the coil will remain in the de-energized state. Therefore,
a power contactor manages the load of current. Hence, buy powercontactors online and heavy load of .
The
power circuit switches are also used for the Power Contactors. When a
relay functions as the switch, it provides electrical power through
the contactors. Contactors have multiple functions like they normally
open the current and sometimes when the current load shuts off, then
the coil will remain in the de-energized state. Therefore, a power
contactor manages the load of current. Hence, buy power contactors
online and avoid the heavy load of current.
1.
Operational principle: -
The
operating principle of the contactors is very simple in nature.
Whenever the contactor's electromagnetic coil is energized, then the
electromagnetic field is produced. This electromagnetic field
attracts the metallic rod towards the gap inside the hollow of the
cylindrical magnet.
2. Arc
suppression:-
The
failure of the contact protection results in the occurrence of
electric current. And the electric arcing causes a significant
degradation of the contacts, which suffers from significant damage.
An electrical arc occurs between the two contact points (electrodes)
i.e., the transition from a closed to an open or from an open to a
closed. The break arc is typically more energetic and thus more
destructive.
Most of
the control contactors are of low voltages (600 volts and less) and
are air break contactors; air at atmospheric pressure surrounds the
contacts and extinguishes the arc when interrupting the circuit.
Modern medium-voltage AC motor controllers use vacuum contactors.
3. IEC
utilization categories:-
The
current rating of the contactor depends on the utilization category.
Example, IEC categories in standard 60947 are described as:
AC-1 -
Non-inductive or slightly inductive loads, resistance furnaces
AC-2 -
Starting of slip-ring motors: starting, switching-off
AC-3 -
Starting of squirrel-cage motors and switching-off only after the
motor is up to speed. (Make Locked Rotor Amps (LRA), Break Full Load
Amps (FLA))
AC-4 -
Starting of squirrel-cage motors with inching and plugging duty.
Rapid Start/Stop. (Make and Break LRA)
Relays
and auxiliary contact blocks are rated according to IEC 60947-5-1.
AC-15 -
Control of electromagnetic loads
DC-13 -
Control of electromagnets
(sources from wiki)
Ratings:-
Contactors
are rated based on the load current per contact (pole), maximum fault
withstands current, duty cycle, design life expectancy, voltage, and
coil voltage. A general purpose motor control contactor may be
suitable for heavy-duty large motors. It is also called "definite
purpose" contactors. They can be adapted to such applications
like air-conditioning compressor motor starting.
NEMA:-
NEMA
contactors for low-voltage motors (less than 1,000 volts) are rated
according to NEMA size, which gives maximum current rating. Ratings
by horsepower is attached to the induction motors. NEMA standard
contactor sizes are designated.
The
above information on power cantactors will help you to buy a good
power contactor. It can be shopped on the trusted portal –
Eleczo.com as it is one of the leading E-Commerce platforms in India.
We are siemens power contactor suppliers and schneider powercontactor distributors. We provide a wide range of discounts and
offers. You also check our abb power contactors catalog for
technical specifications.
Your
online shopping is just a click away - https://www.eleczo.com/